Link Management screen Field Definitions
Field Name Values Description
Monitor Link fields
IP Address to
Ping
a.b.c.d
0-255
This is the IP address of the target
endpoint to be pinged.
Pings per Test 1-999 This field determines how many
pings will be generated by the
Start Now command.
Response
Timeout
500 – 5000
milliseconds
The duration after which a ping
will be considered to have failed.
Ping Size in
Bytes
32 – 128 bytes This field determines how long or
large the ping will be.
Timer Interval
between Pings
0 or 30 – 6000
minutes
This field determines how long of
a wait there is between one ping
and the next.
Start Now
command
button
-- Initiates pinging.
Clear
command
button
-- Erases ping parameters in
Monitor Link field group and
restores default values.