Terminal Adapter AT Commands & S-Registers
Sets the value of an S-register, where r is the number of the S-register, and n
is the value you want to set.
Sr? Read S-Register
Values: r = 05 (S1 is read only) , 7, 8, 10, 25, 32, 34,
50, 52-57, 75-77, 80; n varies
Default: None
Reads the value of an S-register, where r is the number of the S-register.
Vn Terse/Verbose Result Codes
Values: n = 0 or 1
Default: V1 (Verbose)
Controls whether the TAs result codes display as digits (terse) or as words
(verbose). (Use the Q command to enable or disable the display of result
codes.)
V0 Enable terse result codes.
V1 Enable verbose result codes.
Xn Connect Messages
Values: n = 0-5
Default: X2 (Enable all messages) and
(Disable printing CLI with CONNECT message)
Selects the result code messages that the TA sends to the computer.
X0 Enables messages OK, CONNECT, RING,
NO CARRIER, and ERROR (terse result
codes 04).
X1 Enables all messages except BUSY (terse
result codes 05, 1014, 1719, 28, and
32). If a call is placed to a busy line, NO
CARRIER displays.
X2 Enables all messages (terse result codes 0
5, 7, 1014, 1719, 28, and 32).
X4 Disables printing Calling Line Identification
(CLI) at the end of the CONNECT message
line. This command does not affect X0, X1,
nor X2.